New Design Autoclavable Dual Function Sterilize for Intramedullary Nail and Kirschner Wire Operation Trauma Surgery Drill

  • Description
Product Detail

    New design autoclavable dual function sterilize for intramedullary nail and  kirschner wire operation trauma surgery drill

    Application

    Suitable for all kinds of brands of intramedullary nail and the kirschner wire operation.Center hole diameter is 4.0mm. Because of precise concentricity , especially spindle hole directly,improve the accurancy of operation and make the operation more perfect.


    Specification

    Diameter of drill chuck

    0-8mm

    Input voltage

    110V-240V/50Hz

    Output power

    =70W

    Battery capacity

    2500mA/h

    Rated speed

    ?1000rmp

    Rating torque

    6.3Nm

    Charging voltage

    14.4V

    Sterilization

    HTHP

    Sterilizing temperature

    134°C-138?

    Noise

    =60db


    Standard Configuration

    1.  One handpiece 

    2.  Two batteries

    3.  One charger

    4.  One aseptic battery transfer ring

    5.  One operating manual

    6.  One guarantee card 

    7.  One certificate


    Warranty:

    The handpiece guarantees for 1 years, the battery a guarantee for 3 months.


    Advantages:

    1.Integrated Design

      1.1.With this design, the bone drill and saw  have excellent sealing.Therefore, when the device is sterilizted, the motor will be damaged less.

      1.2.With this design, the decomposition of vibration is strong ,so that the noise is very small.

    2.Ergonomic Design, Feel Comfortable

      In the design, the weight of top and bottom is almostly same, so it is avoid hand fatigue when using the product.

    3.Large Battery Capacity

      The battery capacity is larger than similar products in the market to make the power to satisfy the customers' needs.

    4.Imported Motor

      It can increase operation efficiency and precision.


    Notes

    1?Before the operation,the bone drill must be sterilized according to the sterilization.Battery and charger must not be sterilized.

    2?Before the operation,the battery must be filled,and the filled battery must be cooled and then put into the handpiece.

    3?After use,must to be cleaned,then remove the battery.And don’t put the battery and the handpiece together.Do not drop impact , to damage the battery. 

    4?Don’t put the battery in the place where the temperature is higher than 40?

    5?If there is abnormal phenomena during the operation,stop using it.

    6?Prohibited in flammable, explosive materials nearby

    7?If don’t use for long time, the battery should be regularly charged to ensure the battery life.

    Find new design autoclavable dual function sterilize for intramedullary nail and kirschner wire operation trauma surgery drill at Pusm Medical - one of the leading professional manufacturers and suppliers in this field. With wide experience and expertise, we warmly welcome you to buy or wholesale our quality products and customized orders are also welcomed.

Send your message to this supplier
To:  

Shenyang Pusm Medical Device Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>